Metadata for Float Type: APEXIR_TSO1

internal ID number                      1963
transmission ID number                  5049
transmission type                       IRIDIUM
instrument type                         APEXIR_TSO1
IRIDIUM program number                  n/a
WMO ID number                           5901316
WMO instrument type (table 1770)        846
WMO recorder type (table 4770)          88
start time [dd mm yyyy hh mm (Z)]       01 10 2006 20 33
status of start time                    as recorded
launch time [dd mm yyyy hh mm (Z)]      01 10 2006 23 01
status of launch time                   as recorded
launch position [lat latm lon lonm]     -23. -59.9 83. 0.0
status of launch position               as recorded
delay of first down time [hours]        03
down time [days]                        -999.
up time [hours]                         -999.
transmission repetition rate [sec]      -999.
clock drift [hours/hours]               0.
last cycle                              n/a
========================================
calib eq 1 for salinity                 sslope*cnts+soff
calib coef for salinity                 SSLOPE=0.001; SOFF=0.0;
calib eq 1 for temperature              tslope*cnts+toff
calib coef for temperature              TSLOPE=0.001; TOFF=0.0;
calib coef for O2 matrix                c00=3.17242e+03; c01=-1.07261e+02; c02=2.13316e+00; c03=-1.79234e-02;
calib coef for O2 matrix                c10=-1.73981e+02; c11=5.10262e+00; c12=-9.85758e-02; c13=8.02240e-04;
calib coef for O2 matrix                c20=3.95600e+00; c21=-9.81040e-02; c22=1.85346e-03; c23=-1.42536e-05;
calib coef for O2 matrix                c30=-4.26337e-02; c31=8.78820e-04; c32=-1.64409e-05; c33=1.13709e-07;
calib coef for O2 matrix                c40=1.76896e-04; c41=-2.95502e-06; c42=5.55039e-08; c43=-3.08493e-10;
calib coef for BPhase                   p0=-8.02266e+00; p1=1.18753e+00; p2=0.00000e+00; p3=0.00000e+00;
calib eq 1 for pressure                 pslope*cnts+poff
calib coef for pressure                 PSLOPE=0.1; POFF=0.0;
calib eq 1 for voltage                  vslope*cnts+voff
calib coef for voltage                  VSLOPE=0.0776; VOFF=0.4869;
calib eq 1 for vacuum                   vacslope*cnts+vacoff
calib coef for vacuum                   VACSLOPE=0.2952; VACOFF=-30.0946;
========================================
conductivity calibration date           26 01 2006
temperature calibration date            26 01 2006
pressure calibration date               23 01 2006
oxygen calibration date                 30 01 2006
float manufacturer                      Webb
float serial number                     2671
PI                                      Stephen Riser
principal investigator address          UW, Seattle
originating country                     USA
float deployer                          Simon Wadsworth
float deployer address                  NIWA, Wellington
deployment type                         R/V
deployment platform                     Kaharoa
deployment cruise id                    n/a
profile at deployment                   n/a
nominal drift pressure [dbar]           1000
cycles for drift pressure               1
nominal profile pressure [dbar]         2000
cycles for profile pressure             1
Profile Sampling Method                 continuous
pump type                               260ml
conductivity sensor type                SBE41CP
conductivity sensor manufacturer        SBE
conductivity sensor serial number       1510
temperature sensor type                 SBE41CP
temperature sensor manufacturer         SBE
temperature sensor serial number        1510
pressure sensor type                    2900 PSIA
pressure sensor manufacturer            DRUCK
pressure sensor serial number           9955
oxygen sensor type                      3830
oxygen sensor manufacturer              Aanderaa
oxygen sensor serial number             0678
battery type                            Alkaline and lithium
initial battery voltage [volt]          14.8
ROM version                             032306
Board serial number                     5049
Board version                           APF-9i
comment                                 n/a