RECOVERY program log file 03 MAY 2001 01:01:45.10 RECOVER: Current data recovery information -------------- : DOS command line: D:\WRKH300\RECOVER.EXE /PATHD:\ABC01 /50 Destination path: D:\ABC01 RECOVER: Current ADCP hardware information -------------- : 03 MAY 2001 01:01:45.10 , 01/05/03,01:54:05 (PC time , ADCP time) 03 MAY 2001 01:01:45.10 Sent command (RF) with ADCP response: RF = 62028413,27897856 ---- Rec space used (bytes), free (bytes) >03 MAY 2001 01:01:45.16 Sent command (RR) with ADCP response: Recorder Directory: Volume serial number for device #0 is 1561-1bd5 ABC01000 000 9148695 05-01-01 0:53:04a r a [ 2] ABC01001 000 7612133 05-01-01 5:57:42a r a [ 4470] ABC01002 000 8560240 05-01-01 11:37:04a r a [ 8187] ABC01003 000 7866521 05-01-01 5:11:02p r a [12367] ABC01004 000 8896500 05-01-01 10:42:36p r a [16209] ABC01005 000 960033 05-02-01 5:08:56a r a [20553] ABC01006 000 5122048 05-02-01 1:13:26p r a [21022] Bytes used on device #0 = 48166170 Volume serial number for device #1 is 0000-013b ABC01006 001 4593664 05-02-01 2:58:02p r a [ 2] ABC01007 000 9268579 05-03-01 1:53:42a r a [ 2245] Bytes used on device #1 = 13862243 Total capacity = 89931776 bytes Total bytes used = 62028413 bytes in 9 files Total bytes free = 27897856 bytes >03 MAY 2001 01:01:45.38 Sent command (PS0) with ADCP response: Instrument S/N: 1410 Frequency: 307200 HZ Configuration: 4 BEAM, JANUS Match Layer: 10 Beam Angle: 20 DEGREES Beam Pattern: CONVEX Orientation: DOWN Sensor(s): HEADING TILT 1 TILT 2 TEMPERATURE Temp Sens Offset: -0.40 degrees C CPU Firmware: 16.15 [0] Boot Code Ver: Required: 1.13 Actual: 1.13 DEMOD #1 Ver: ad48, Type: 1f DEMOD #2 Ver: ad48, Type: 1f PWRTIMG Ver: 85d3, Type: 4 Board Serial Number Data: 21 00 00 02 48 AC 38 09 REC727-1000-04A CF 00 00 00 98 EB EC 09 CPU727-2000-00F C4 00 00 00 9A 9B 12 09 PIO727-3000-04C 8C 00 00 02 48 BC D3 09 DSP727-2001-04F >03 MAY 2001 01:01:46.20 Sent command (PS3) with ADCP response: Beam Width: 3.7 degrees Beam Elevation Azimuth 1 -70.00 270.00 2 -70.00 90.00 3 -70.00 0.01 4 -70.00 180.00 Beam Directional Matrix (Down): 0.3420 0.0000 0.9397 0.2419 -0.3420 0.0000 0.9397 0.2419 0.0000 -0.3420 0.9397 -0.2419 0.0000 0.3420 0.9397 -0.2419 Instrument Transformation Matrix (Down): Q14: 1.4619 -1.4619 0.0000 0.0000 23952 -23952 0 0 0.0000 0.0000 -1.4619 1.4619 0 0 -23952 23952 0.2661 0.2661 0.2661 0.2661 4359 4359 4359 4359 1.0337 1.0337 -1.0337 -1.0337 16936 16936 -16936 -16936 Beam Angle Corrections Are Loaded. >03 MAY 2001 01:01:46.48 Sent command (AC) with ADCP response: ACTIVE FLUXGATE CALIBRATION MATRICES in NVRAM Calibration date and time: 9/15/1997 16:02:20 S inverse Ú ¿ Bx ³ 2.7322e-01 -2.7048e-01 -2.9393e-02 -8.6070e-04 ³ By ³ -2.2604e-02 -1.1113e-02 -3.6987e-01 8.8249e-03 ³ Bz ³ 1.5608e-01 1.2259e-01 1.8306e-02 -1.8668e-01 ³ Err ³ 2.9098e-01 2.9432e-01 -1.6248e-02 4.3497e-01 ³ À Ù Coil Offset Ú ¿ ³ 3.3480e+04 ³ ³ 3.3725e+04 ³ ³ 3.4660e+04 ³ ³ 3.4609e+04 ³ À Ù Electrical Null Ú ¿ ³ 34471 ³ À Ù TILT CALIBRATION MATRICES in NVRAM Calibration date and time: 9/15/1997 15:48:20 Average Temperature During Calibration was 24.0 øC Up Down Ú ¿ Ú ¿ Roll ³ -9.3489e-07 -1.9664e-05 ³ ³ 6.2216e-07 1.9665e-05 ³ Pitch ³ -1.9404e-05 4.9832e-07 ³ ³ -1.9736e-05 3.6338e-07 ³ À Ù À Ù Ú ¿ Ú ¿ Offset ³ 3.1259e+04 3.1288e+04 ³ ³ 3.0541e+04 3.2664e+04 ³ À Ù À Ù Ú ¿ Null ³ 33332 ³ À Ù >03 MAY 2001 01:01:46.97 Sent command (RN?) with ADCP response: Current deployment name = ABC01 >03 MAY 2001 01:01:47.03 Sent command (DEPLOY?) with ADCP response: Deployment Commands: RE ----------------------- Recorder ErAsE RN ----------------------- Set Deployment Name WD = 111 100 000 --------- Data Out (Vel,Cor,Amp; PG,St,P0; P1,P2,P3) LN = 025 ----------------- Number of depth cells (1-128) LP = 00001 --------------- Lowered Pings per Ensemble (0-16384) LS = 0800 ---------------- Depth Cell Size (cm) LV = 200 ----------------- Mode 1 Ambiguity Vel (cm/s radial) LZ = 030,220 ------------- Amp, Corr Thresholds (0-255) TE = 00:00:01.00 --------- Time per Ensemble (hrs:min:sec.sec/100) TF = **/**/**,**:**:** --- Time of First Ping (yr/mon/day,hour:min:sec) TP = 00:01.00 ------------ Time per Ping (min:sec.sec/100) TS = 01/05/03,01:54:07 --- Time Set (yr/mon/day,hour:min:sec) EA = +00000 -------------- Heading Alignment (1/100 deg) EB = +00000 -------------- Heading Bias (1/100 deg) ED = 00000 --------------- Transducer Depth (0 - 65535 dm) ES = 35 ------------------ Salinity (0-40 pp thousand) EX = 11111 --------------- Coord Transform (Xform: Type,Tilts,3 Bm,Map) EZ = 0011101 ------------- Sensor Source (C,D,H,P,R,S,T) Press any key to continue03 MAY 2001 01:02:07.07 Sent command () with ADCP response: CK ----------------------- Keep Parameters as USER Defaults CR # --------------------- Retrieve Parameters (0 = USER, 1 = FACTORY) CS ----------------------- Start Deployment >03 MAY 2001 01:02:46.95 ATTENTION: RECOVER could not put ADCP to sleep 03 MAY 2001 01:02:47.01 ----- RECOVER TERMINATED ----- (exitcode = 5, ymodem = 0)