6 50 1.0 11 9 1988 1 1 700 IN W 37.9 57.00 37.8 74.50 2861 8.50 60112 59049 5.5 2 2 700 OUT S 45.3 37.00 43.7 37.00 2861 10.50 60252 61063 3.5 3 3 700 IN E 49.6 47.50 49.6 47.50 2850 10.50 63650 62777 9.0 4 4 700 OUT N 42.7 50.50 42.5 50.50 2842 13.00 63995 64596 12.5 5 5 700 IN W 41.9 55.00 41.7 55.00 2834 8.50 66793 66236 6.5 6 6 700 OUT N 50.3 53.50 50.3 53.50 2827 14.50 67032 67732 6.0 7 7 700 IN E 58.1 55.00 54.5 55.50 2816 15.00 71086 70196 2.5 8 8 700 OUT S 40.9 50.00 40.8 50.00 2817 11.50 71381 72139 10.5 9 1 700 IN ENE 77.4 17.00 77.4 17.00 2308 9.50 237463 236691 1.0 10 2 700 OUT W 71.8 9.50 71.4 10.00 2331 2.00 237476 238629 0.5 11 3 700 IN S 70.1 13.50 65.7 13.00 2262 2.50 241996 240873 2.5 12 4 700 OUT N 77.2 11.50 71.1 12.00 2229 6.50 242006 243248 3.0 13 5 700 IN W 79.8 14.00 78.8 14.00 2184 3.00 246828 245637 3.0 14 6 700 OUT E 77.4 10.00 75.5 10.00 2165 5.50 246839 248011 3.5 15 7 700 IN N 80.2 12.00 80.0 12.00 2134 2.00 251533 250384 2.0 16 8 700 OUT S 79.2 10.50 77.1 11.00 2096 5.50 251545 252714 2.5 17 9 700 IN W 75.8 9.00 74.8 9.50 2189 0.50 256969 255853 0.5 18 10 700 OUT NE 77.4 16.50 77.0 16.50 2137 6.50 257005 257591 4.5 19 1 700 IN ENE 66.1 12.00 65.9 12.00 2178 0.50 281363 280181 0.5 20 2 700 OUT W 69.1 11.00 69.0 11.00 2177 1.50 281375 282609 0.5 21 3 700 IN S 62.7 7.50 62.6 8.00 2185 0.50 286214 285081 0.5 22 4 700 OUT N 72.4 14.50 72.3 14.50 2167 3.00 286224 287428 0.5 23 5 700 IN W 70.9 13.00 70.1 13.00 2153 4.00 291959 291309 3.0 24 6 700 OUT E 66.4 11.50 65.0 11.50 2147 3.00 291969 293119 3.0 25 7 700 IN N 66.6 14.00 66.4 14.00 2143 2.00 295936 295167 1.0 26 8 700 OUT S 68.8 7.50 68.7 7.50 2147 0.50 295943 296974 0.5 27 9 700 IN SE 68.2 11.00 68.1 11.50 2154 2.50 299199 298031 1.0 28 10 700 OUT N 67.5 10.00 67.4 10.00 2157 1.50 299210 300382 1.5 29 1 850 IN N 41.2 55.00 41.0 55.00 998 2.50 390249 389053 1.0 30 2 850 OUT S 39.7 68.50 39.7 68.50 1000 2.00 390260 391444 0.5 31 3 850 IN E 42.4 145.50 42.4 145.50 1000 15.50 395172 393956 13.5 32 4 850 OUT W 39.8 58.00 39.6 58.00 1018 11.50 395264 396509 11.5 33 5 850 IN S 39.3 59.00 39.0 59.50 1012 0.50 399574 398344 0.5 34 6 850 OUT N 41.8 71.50 41.8 72.00 1006 5.50 399587 400766 1.0 35 7 850 IN NW 45.5 68.50 45.5 68.50 1013 16.00 403740 402945 2.0 36 8 850 OUT E 44.9 149.50 44.8 149.50 1043 2.00 403748 404965 2.0 37 1 850 IN ENE 43.0 40.50 42.4 40.50 984 1.50 433647 432983 0.5 38 2 850 OUT W 47.4 41.50 46.4 41.50 981 3.50 433658 434946 1.0 39 3 850 IN S 47.2 54.00 47.2 54.00 990 9.00 438953 437678 2.0 40 4 850 OUT N 40.6 59.00 40.6 59.00 993 1.00 438972 440226 1.0 41 5 850 IN W 46.4 55.50 46.0 55.50 999 4.00 444006 442753 3.5 42 6 850 OUT E 43.5 137.50 43.4 137.50 997 5.50 444022 445259 3.5 43 7 850 IN S 46.3 45.00 46.0 45.00 992 5.50 451008 449720 5.5 44 8 850 OUT N 39.7 57.50 39.6 57.50 992 5.00 451034 452354 5.0 45 1 850 IN ENE 56.5 98.50 56.1 98.50 1019 5.50 499841 498503 0.5 46 2 850 OUT W 43.4 50.00 41.8 52.00 1015 9.50 499851 500386 1.0 47 3 850 IN S 50.0 90.50 49.1 90.50 1018 3.50 502300 501347 3.5 48 4 850 OUT N 45.1 112.50 44.4 112.50 1017 3.00 502324 503522 3.0 49 5 850 IN NNE 44.0 117.00 43.5 117.00 1029 2.50 508332 507067 2.5 50 6 850 OUT SSE 43.3 147.00 43.0 147.00 1027 19.00 508343 509502 3.0 GILBERT88 First line holds: Number of flights for storm Number of passes for storm DR (see top-level README file for explanation) Starting day, in day, month and year Order of variables: Global pass number Local pass number, i.e., the pass number for the local flight The standard pressure for the pass, in mb. String, either "IN " or "OUT" for inward or outward pass String giving approx. location of the pass relative to the storm center Maximum (scalar) windspeed in that pass, in storm-relative coords Radius (distance from storm center) at which max windspeed is found Maximum tangential wind for that pass Radius at which max. tan. wind is found Minimum height of the standard pressure surface, in meters above sealevel Radius at which min. height of standard pressure surface is found Time value for the innermost bin that has data Time value for the outermost bin that has data Radius of the innermost bin that has data Radii are in km and winds in meters per second